Prime Blocks Tech

One structural system, every design.

A Prime Blocks Tech panel is an expanded polystyrene core held between two galvanized welded-wire meshes, tied through the core with steel connectors. On site, 4,000 psi structural mortar is applied to both faces. The result is a monolithic sandwich that carries load, insulates and finishes in one operation.

1234 1. Structural mortar, 3 cm each face 2. EPS core — 60 to 180 mm 3. Galvanized welded mesh, both faces 4. Dowels epoxy-set into the slab

Why every plan in this catalogue is drawn for it

Because the details do not change. A wall base is a wall base, a corner is a corner, an opening jamb is an opening jamb — on a 144 sq ft studio and on a 2,500 sq ft courtyard house. Sheet A-4.0 of every set carries the same six details, sized to the panel that design uses.

It also means the quantities fall straight out of the drawing: panel area, mortar volume, partition length, connector runs. That is why we can quote a kit at all.

The panel range

Panels are named for the EPS core thickness in millimetres. The finished thickness adds roughly 3 cm of mortar per face.

PanelCoreFinishedNominal RTypical use
PBT6060 mm3.6″R-14Non-structural partition, screens
PBT8080 mm4.4″R-18Interior partitions, small structures
PBT100100 mm5.2″R-23Small cabins and ADUs
PBT120120 mm6.0″R-27Standard exterior wall, mild climates
PBT140140 mm6.8″R-32Standard exterior wall, mixed climates
PBT160160 mm7.6″R-36Cold climate, taller walls
PBT180180 mm8.4″R-41Cold climate, high load
Roof / floor panelClear spanBuild-up
PBT-Slab 160to 14′EPS core slab panel with mesh both faces, concrete topping
PSG2-200to 20′EPS blocks over galvanized steel joists, mesh soffit, topping
PSG3-240to 26′Deeper joist, same build-up
PSG6-300to 32′Deepest joist — the widest rooms in the catalogue

Read this part

What we do not claim.

Fire resistance. No fire-resistance rating is claimed anywhere on this site or on the drawing sheets. Where your code requires a rated assembly, obtain a current tested-assembly report for the specific build-up and submit that.

Structural values. The spans and thicknesses given here are the system's ordinary working range, not a design. Loads for your site — snow, wind, seismic — and therefore the panel selection, connections, foundation and lateral system are the responsibility of the engineer of record.

R-values. The figures above are nominal for the core and render, before thermal bridging through the connectors and before any assembly testing. Treat them as a comparison between panels, not as a compliance number.

Evaluation reports. Ask us for the current technical evaluation report before you submit to an authority having jurisdiction, and check its renewal date. An expired report will be rejected.